Verify sleep and wake behavior first
Observe the current trace of each glove and perform a fresh Bluetooth scan. Test unconnected sleep after one minute, connected operation beyond one idle minute, sleep one minute after a disconnection, motion wake-up and charger wake-up. A cached device name in the phone does not prove that the glove is currently advertising.
Record glove ID and side, firmware version, battery revision, room temperature, starting charge and the measurement instrument. Use the same conditions for both hands.
Validate at least 30 days of standby
- Measure whole-glove average sleep current over a period that includes periodic pulses. The strict project target is below 20 microamps.
- Keep one fully charged pair in the test room. Record remaining charge on days 7, 14, 21 and 28 under the same procedure, without recharging.
- Leave a second fully charged pair asleep for 30 uninterrupted days. On day 30, wake both by motion, connect them and record one fresh light hit from each side using battery power only.
Validate at least five hours of continuous training
First estimate runtime from usable capacity under the same load divided by measured average training current. Then perform a full run with both gloves fully charged and unplugged, 800 Hz sensing active, Bluetooth streaming and repeated pressure triggers at a fixed cadence.
Log the last fresh valid sample from each glove and confirm why the stream ended. If a phone or wireless fault ends the run, correct the fault and repeat. The usable runtime of the pair is the shorter of the two glove runtimes. Both sides must still deliver valid punch data at five hours to meet the five-hour target.
Need a traceable validation plan for your project?
Tell us the target configuration, firmware and acceptance criteria. We can align test records with your OEM or ODM project.
Discuss a validation project