Verify sample continuity before testing distance
Each glove samples pressure and six-axis motion at 800 Hz, producing 48,000 sample sets in 60 seconds. Two gloves produce 96,000 sets. Log hand, sample sequence, sample timestamp and phone arrival time separately for each stream.
Sequence numbers reveal missing or repeated samples. Arrival time reveals late bursts that may freeze the live display even when the samples eventually arrive.
Measure both gloves at one meter and across the venue
- About 1 m: stream both gloves for at least three minutes and record RSSI for each link. The project target is stronger than -60 dBm.
- 5 to 35 m: repeat at marked distances and record disconnects, missing samples and the longest interval without fresh data. Testing at 35 m challenges the project target of stable transmission beyond 30 m.
- At the bag: use the coach's normal phone position and include natural body obstruction, turning and alternating hands. Report phone model, orientation and venue conditions.
Time recovery from availability to fresh data
Test left-only loss, right-only loss and both-glove loss. Record the last valid data, the time the glove becomes reachable again, link restoration and the first fresh valid sample. The first-fresh-data time minus reachable-again time is business recovery latency.
Repeat on supported iOS and Android phones. Report successes, failures, median and longest successful recovery time. The app should identify the affected hand, keep the healthy stream active and return to green only after both sides are delivering fresh data.
Need a traceable validation plan for your project?
Tell us the target configuration, firmware and acceptance criteria. We can align test records with your OEM or ODM project.
Discuss a validation project