TEST METHOD

How to Test Smart Boxing Glove Counting Accuracy for Single Punches Combinations and Air Swings

A repeatable method for measuring missed punches, duplicate counts and false triggers instead of relying on the final total alone.

Paired smart boxing gloves prepared for counting validation
Paired smart boxing gloves prepared for counting validation

Create an independent record of every contact

A final count of 20 does not prove that all 20 punches were detected correctly. One missed light punch and one duplicated hard punch can still produce the same total. Record glove side, sample time, raw pressure, three-axis acceleration, three-axis angular velocity and every app event.

Use a camera angle that clearly shows the glove-to-bag contact point. Align the video and sensor log with one visible tap, exclude that tap from scoring, and define the permitted matching time tolerance before the test begins.

Test single punches combinations and air swings separately

  • Single punches: allow pressure to return near background before the next strike. Each real contact should produce one distinct peak and one event.
  • Combinations: use fixed three-punch sequences at a comfortable pace and a faster pace. Confirm three contacts, three distinguishable peaks and three events in each sequence.
  • Air swings and off-zone contacts: test complete misses and contacts outside the sensing area. Both conditions should produce zero valid-punch events.

Report misses duplicates and false triggers

Match every video-confirmed contact to no more than one app event using side and time. A contact without a matching event is a miss. Additional events matched to the same contact are duplicates. Events recorded during air swings are false triggers.

Report miss rate for single punches and combinations separately, duplicate-event count, and false-trigger rate per swing. After changing a threshold or timing rule, repeat all three test groups because recovering light punches may also increase false triggers or split one contact into two events.

For questions, please contact reed.zhong at reed@wavemill.cn.

Need a traceable validation plan for your project?

Tell us the target configuration, firmware and acceptance criteria. We can align test records with your OEM or ODM project.

Discuss a validation project