Define sleep wake and connected behavior
- Awake but unconnected: after one minute without a hit or other activity, stop advertising and enter low-power sleep.
- Connected: remain active even when no punch occurs for more than one minute so the next strike can be recorded without a new pairing cycle.
- Just disconnected: if there is no activity for one minute, return to sleep to prevent accidental battery drain.
- Asleep: motion or connecting the charger should wake the glove and make it discoverable in a fresh app scan.
Use current measurements to set realistic targets
Standby runtime depends on average sleep current, battery self-discharge and the low-voltage cutoff. The WM-BF design reference is about 20 microamps in sleep, with a strict test target below 20 microamps. At exactly 20 microamps, 30 days consumes about 14.4 mAh before self-discharge and cutoff margin are considered.
Training runtime must use average current measured during representative 800 Hz sensing and Bluetooth streaming, including repeated contacts. A brief transmit peak is not the average, and nameplate battery capacity may exceed the usable capacity available before device cutoff.
Treat 30 days and five hours as validation targets
The current project targets are at least 30 days of standby and at least five hours of continuous training for the pair. These are different operating states and should never be combined into one runtime claim.
Public product statements should identify the tested firmware, battery, temperature and use condition. Until a released configuration has passed the full protocol, present these figures as design or validation targets rather than guaranteed performance for every sample.
Need a traceable validation plan for your project?
Tell us the target configuration, firmware and acceptance criteria. We can align test records with your OEM or ODM project.
Discuss a validation project