TEST METHOD

How Smart Boxing Gloves Measure Punch Force Using Sensor Calibration and 800 Hz Peak Detection

A technical explanation of per-glove pressure calibration, background and light-hit thresholds, and calibrated peak detection during bag contact.

Flexible pressure sensor and calibration electronics
Flexible pressure sensor and calibration electronics

Use a consistent pressure-sensor architecture

A flexible pressure sensor is placed in the intended striking area of each glove. Using one qualified sensor design reduces variation, but it does not remove the effects of assembly, lining and load path. Finished-glove calibration is still required.

The sensor and IMU are sampled at 800 Hz so the system can observe the short contact event and associate its pressure peak with the motion window that preceded it.

Create a calibration curve for each glove

Mount the finished glove on a controlled loading rig and apply several known reference loads through the striking surface. Record the reference value and raw sensor output at each point, fit the conversion equation, and store the parameters in the glove electronics.

Document the glove ID, sensor revision, loading fixture, contact area, reference-instrument status and calibration date. A number without these conditions is difficult to reproduce across samples.

Track the valid-contact peak at 800 Hz

Measure background pressure while the glove is worn but not striking, then use controlled light hits to set a threshold. Pressure below the threshold does not create a force result even when the IMU shows an air swing.

After the threshold is crossed, follow the same contact to its calibrated maximum and report the equivalent load as kgf. For dynamic-impact research or certified competition measurement, use a reference system designed and calibrated for that purpose; a training glove reading should not be presented as a universal absolute-force standard.