Evidence before claims
Use repeatable methods, controlled conditions and traceable records to evaluate smart boxing sensors, connected electronics and finished-product performance.
The values in these articles are test criteria or project targets unless a result is explicitly tied to a tested sample, firmware version and test record. They should not be read as unconditional performance guarantees.
Punch detection & AI recognition
Protocols for valid-hit detection, counting accuracy and Straight, Uppercut and Hook recognition.
How Smart Boxing Glove Sensors Detect a Valid Punch
How 800 Hz pressure and motion sampling, a calibrated threshold and peak tracking separate a real bag contact from an air swing and count one contact only once.
Read test method →01.02 · TEST METHODHow to Test Smart Boxing Glove Counting Accuracy for Single Punches Combinations and Air Swings
A repeatable method for measuring missed punches, duplicate counts and false triggers instead of relying on the final total alone.
Read test method →01.03 · TEST METHODHow to Test AI Punch Recognition Accuracy for Straight Uppercut and Hook
A train-and-validation protocol for Straight, Uppercut and Hook recognition using labeled 500 ms IMU windows, held-out sessions and per-class results.
Read test method →01.04 · TEST METHODHow AI Smart Boxing Gloves Recognize Straight Uppercut and Hook
The engineering path from pressure-confirmed contact to a 500 ms six-axis motion sequence and AI classification of Straight, Uppercut and Hook.
Read test method →Hand identification & force data
Methods for left-right pairing, equivalent-load calibration and 800 Hz peak detection.
How Smart Boxing Gloves Identify Left and Right Hands and Measure Punch Force
How paired Bluetooth identities keep left and right data separate while per-glove pressure calibration converts raw sensor readings into punch-force feedback.
Read test method →02.02 · TEST METHODHow to Pair Left and Right Smart Boxing Gloves and Interpret Punch Force Data
A practical guide to pairing both WM-BF gloves, checking the hand assignment and reading calibrated kgf and Relative Force values correctly.
Read test method →02.03 · TEST METHODHow Smart Boxing Gloves Measure Punch Force Using Sensor Calibration and 800 Hz Peak Detection
A technical explanation of per-glove pressure calibration, background and light-hit thresholds, and calibrated peak detection during bag contact.
Read test method →Bluetooth connection reliability
Repeatable tests for operating range, disconnection behavior and automatic recovery.
How to Test Bluetooth Range Disconnection and Reconnection for Smart Boxing Gloves
A two-glove protocol for signal strength, streaming continuity, missing samples and time to fresh data after a disconnection.
Read test method →03.02 · TEST METHODHow Smart Boxing Gloves Maintain Reliable Bluetooth Connections
How peak-current support, antenna matching, RSSI margin, automatic reconnection and per-hand status monitoring work together in a high-motion environment.
Read test method →Power management & battery runtime
Validation procedures for sleep current, standby targets and continuous training runtime.
Smart Boxing Glove Power Management and Runtime Targets
How one-minute sleep logic, motion and charger wake-up, connected-state behavior and current budgets support standby and training-runtime targets.
Read test method →04.02 · TEST METHODHow to Test Smart Boxing Glove Battery Life for 30 Day Standby and 5 Hour Training
A full-pair battery validation method covering sleep current, weekly charge checks, a 30-day wake-up test and a five-hour loaded training run.
Read test method →04.03 · TEST METHODSmart Boxing Bluetooth Circuit Board Low-Power Test: Sleep, Active and Transport Mode Current
A recorded current-measurement test of one smart-boxing Bluetooth circuit-board sample across active communication, sleep and transport modes, including the measured transitions between states.
Read test method →04.04 · TEST METHODWhat Is the Sleep Current of a Smart Boxing Bluetooth Sensor?
Learn what a microamp sleep-current figure includes, why operating state matters and how to evaluate a smart boxing sensor measurement without confusing a design target with a universal specification.
Read test method →04.05 · TEST METHODWhy Can Transport Mode Use Less Power Than Normal Sleep?
Understand how transport mode can disable more circuits and wake sources than daily sleep, why it is not zero power and how to validate storage behavior and reliable reactivation.
Read test method →04.06 · TEST METHODHow Does Bluetooth Communication Affect Smart Boxing Battery Life?
See how sensor sampling, packet scheduling, connection quality, retransmission and peak current affect the real battery life of connected smart boxing equipment.
Read test method →04.07 · TEST METHODHow to Test the Low-Power Performance of a Smart Boxing Sensor
A practical validation workflow covering battery-side current, sleep and wake behavior, Bluetooth connection, real training load and long-duration runtime testing.
Read test method →04.08 · TEST METHODCan Circuit-Board Power Consumption Predict Whole-Device Battery Life?
Learn when capacity divided by average current is useful, why measurement boundary and usable capacity matter, and how to turn an estimate into a defensible smart boxing runtime result.
Read test method →